Rack Mount Programmable Power Supplies

ADM stocks the MEAN WELL range of programmable rack mount power supplies.

MEAN WELL has three series of programmable rack mount power supplies:

Series

Typical Power Output*

RCP-1600

1600 Watts

RCP-2000

2000 Watts

DRP-3200

3200 Watts
*check data sheet for actual model selected

MEAN WELL rack mount power supplies are based on a modular design.

1U low profile racks are available that will accommodate either 3, or 5 power supply units. The power supply units themselves all have a current sharing feature, so that they can be connected in parallel.

All MEAN WELL’s rack mount power supplies are ‘hot swappable’, so you don’t need to power down to swap out a power supply that may have failed and all models have a remote ON/OFF function. This makes them highly desirable for use in data centres.

RCP-1600

Mean Well RCP-1600

There are three different models of the RCP-1600 available:

Model

Power Output

RCP-1600-12

12V / 125A

RCP-1600-24

24V / 67A

RCP-1600-48

48V / 33.5A

The rack is ordered as a separate item under part number RHP-1U.

Mean Well RHP-1U

Holding 5 power supplies, you have up to 8000 watts of power available, should you opt to use the current sharing function to connect all 5 power supply units in parallel.

There are 3 built-in alarm signals: DC OK, AC OK and Temperature alarm.

The output voltage and current can be programmed via applying an external voltage to the control inputs. This means the power supplies output can be varied throughout a process using a PLC, or other type of controller.

The range of adjustment available is shown in the below table:

Power Supply Unit

Manual VDC Adjust Range

Remote VDC Adjust Range

Remote Current Adjust Range

RCP-1600-12

11.5 ~ 15V

40~125% of the nominal voltage 20~100% of the rated current

RCP-1600-24

23.5 ~ 30V

RCP-1600-48

47.5 ~ 58.8V

There is also an auxiliary power output, which can deliver either 5V @ 0.3A, or 12V @ 0.8A.

RCP-2000

MEAN WELL RCP-2000

The RCP-2000 series power supplies share many of the features and functions found on the RCP-1600 mentioned above.

The RKP-1U mounting rack is ordered separately and can house up to 3 RCP-2000 power supplies.

MEAN WELL RKP-1U

 

Model

Power Output

RCP-2000-12

12V / 100A

RCP-2000-24

24V / 80A

RCP-2000-48

48V / 42A

Using the current sharing function, you enjoy a power output of up to 6000 Watts per rack.

The RCP-2000 boasts a wide range of useful functions, which makes it perfect for use in a wide range of applications:

  • Auxiliary power output: 5V @ 0.3A / 12V @ 0.8A
  • Remote adjustment of output voltage.
  • DC OK Signal
  • AC OK Signal
  • Over Temperature Warning
  • Fan Fail Signal

As with the RCP-1600 remote adjustment of the output voltage is achieved by applying an external voltage to the relevant control terminals on the power supply.

Power Supply Unit

Voltage Adjust Range (Manual)

Voltage Adjust Range (Remote)

RCP-2000-12

10.5 ~ 14V

90 ~ 110% of nominal output voltage

RCP-2000-24

21 ~ 28V

RCP-2000-48

42 ~ 56V

A remote-control unit is available for the RCP-2000 series racj mount power supplies under part number RKP-CMU1.

MEAN WELL RKP-CMU

This allows you to monitor the output voltage of the power supplies, the current draw and temperature level. Alarm signals can be set to warn of a power supply operating outside of expected parameters, giving an early indication that something could be wrong.

DRP-3200

MEAN WELL DRP-3200

The DRP-3200 series programmable rack mount power supplies have recently been added to the MEAN WELL range.

ADM plans to stock these in the future.

The DRP-3200 features a, I2C and supports the PMBus protocol. CANBus protocol support is available as an option. This means the DRP-3200 can easily be integrated into higher level control systems.

As with the RCP-1600, both the output current and output voltages are programmable.

Power Supply Unit

Manual VDC Adjust Range

Remote VDC Adjust Range

Remote Current Adjust Range

DRP-3200-24

23.5 ~ 30V

50~125% of the nominal voltage 20~100% of the rated current

DRP-3200-48

47.5 ~ 58.8V

Again, there are built-in alarm signals to indicate the status of the DC output and to flag if the temperature of the unit exceeds 60°C.

The rack is ordered as a separate item under part number DHP-1UT and holds up to 4 units.

The DRP-3200 features MEAN WELL’s current sharing function, which means one rack can deliver up to 12,800 Watts. In fact, a total of 8 units can be connected in parallel to deliver a total of 25,600 Watts!

1U LOW PROFILE HIGH DENSITY RACK MOUNT POWER SUPPLY

The MEAN WELL DRP-3200 series rack mount power supplies are perfect if you are looking for a 1U low-profile rack mount power supply with a high-power density. 

The MEAN WELL DHP-1UT mounting rack is ordered separately and can accommodate up to 4 DRP-3200 front end rectifiers. All 4 rectifiers can be connected in parallel to deliver up to 12,800 WATTS of power, depending on the actual front-end rectifiers used. 

MEAN WELL DHP-1UT

There are two different front-end rectifiers available: 

Link to Product Information

Link to Product Information

Power Output

DRP-3200-24 

24V / 133A 3192W

DRP-3200-48

48V / 67A 3216W

MEAN WELL front end rectifier for rack mounting

The slimline 1U low profile and high-power density are not the only remarkable features of these power supplies. 

The power supplies are highly efficient, with an efficiency rating of up to 94.5%. 

The front-end rectifiers are also hot swappable, so you don’t have to power the system down in the unlikely event of having to swap a unit over. 

As standard the DRP-3200-24 and DRP-3200-48 support the PMBus communications protocol, CANBus support is optional. This can be used to monitor the status of the power supply and to also trim the output current and, or voltage.  

The output current and voltage can also be trimmed by applying an analogue voltage signal. This means these power supplies are compatible with many PLCs and other types of system controllers used in industrial and process automation applications. 

The power supplies can also be switched on and off remotely. A 5V / 0.3A auxiliary output is available to maintain the controller in stand-by mode until it is required again to reactivate the power supply. 

There is also an alarm signal output for remote monitoring of the status of the power supply. 

Rack Mount Power Supplies for Data Centres

MEAN WELL’S range of rack mount power supplies boast a range of useful features, which makes them ideal for use in data centres.

When selecting a rack mount power supply for use in a data centre you want both reliability and functionality that can forewarn you of any problems that could result in a server going down.

MEAN WELL rack mount power supply is based on a modular design.

1U low profile racks are available that will accommodate either 3, or 5 power supply units. The power supply units themselves all have a current sharing feature, so that they can be connected in parallel.

All of MEAN WELL’s rack mount power supplies are ‘hot swappable’, so you don’t need to power down to swap out a power supply that may have failed and all models have a remote ON/OFF function. This makes them highly desirable for use in data centres.

There are also a number of other features available on various different models.

MEAN WELL RCP-1000 Rack Mount Power System

MEAN WELL RCP-1000

Within the RCP-1000 series there are three different voltage output options available:

Model

Power Output

MEAN WELL RCP-1000-12

12V / 60A

MEAN WELL RCP-1000-24

24V / 40A

MEAN WELL RCP 1000-48

48V / 21A

The 1U low profile rack is available as a separate item under part number RCP-1U.

MEAN WEL RCP-1U

Each rack can hold up to 3 MEAN WELL RCP-1000 rack mount power supplies. Using the current sharing function, you can connect these up in parallel to deliver up to 3000 Watts of power.

The RCP-1000 power supply units have a 5V / 0.3A auxiliary power output, which is very useful for powering cooling fans. As we know, servers do not like running hot, so this is a very useful feature for a power supply that is to be used in a data centre.

There are also two output alarm signals. One for DC OK and one for AC OK. These can be used to give a warning of a failure on either the AC or DC side.

The output voltage can be trimmed manually. The following table shows the adjustment range, depending on the output voltage of the power supply unit:

Power Supply Unit

Voltage Adjust Range (Manual)

Voltage Adjustment Range (Remote)

RCP-1000-12

11.6 ~ 12.4V

90 ~ 110% of nominal output voltage

RCP-1000-24

23.2 ~ 24.8V

RCP-1000-48

46.3 ~ 49.7V

Remote control of the voltage output is achieved by applying external resistance across the appropriate control terminals on the power supply.  This can be applied through the RCP-MU remote control and monitoring unit.

Mean Well RCP-MU

This remote control enables you to monitor the output voltage of the power supplies, the current draw and temperature level. Alarm signals can be set to warn of a power supply operating outside of expected parameters, giving an early indication that something could be wrong.

MEAN WELL RCP-1600 Rack Mount Power System

Mean Well RCP-1600

The RCP-1600 series differs a little from the RCP-1000 in two ways.

Apart from its higher power output, which are detailed in the following table, the 1U rack accepts 5 power supply units instead of 3, giving you a much higher power density from a single rack. Plus both the output voltage and output current can be remotely adjusted.

Model

Power Output

MEAN WELL RCP-1600-12

12V / 125A

MEAN WELL RCP-1600-12

24V / 67A

MEAN WELL RCP-1600-48

48V / 33.5A

The rack is ordered as a separate item under part# RHP-1U.

Mean Well RHP-1U

Holding 5 power supplies means that you have up to a whopping 8000 watts available should you opt to use the current sharing function to connect all 5 power supply units in parallel.

With the RCP-1600 rack power supply system you get 3 alarm signals: DC OK, AC OK and Temperature alarm.

There is a wider range of output voltage adjustment available as well, which is shown in the following table:

Power Supply Unit

Manual VDC Adjust Range

Manual VDC Adjust Range

Remote Current Adjust Range

RCP-1600-12

11.5 ~ 15V

40~125% of the nominal voltage 20~100% of the rated current

RCP-1600-24

23.5 ~ 30V

RCP-1600-48

47.5 ~ 58.8V

With the RCP-1600 series remote adjustment of the voltage and current output is achieved by applying an external voltage to the relevant control terminals.

The auxiliary output can also deliver either 5V @ 0.3A, or 12V @ 0.8A.

Unlike the RCP-1000, there is no remote control unit available for the RCP-1600 power supplies. However, the fact that is uses external voltage for remote operations enables integration into many automation control systems.

MEAN WELL RCP-2000 Rack Mount Power System

The RCP-2000 series power supplies share many of the features and functions found on both the RCP-1000 and RCP-1600 mentioned above.

MEAN WELL RCP-2000

Models

Power Output

MEAN WELL RCP-2000-12

12V / 100A

MEAN WELL RCP-2000-24

24V / 80A

MEAN WELL RCP-2000-48

48V / 42A

The RKP-1U mounting rack is ordered separately and can house up to 3 RCP-2000 power supplies.

MEAN WELL RKP-1U

Using the current sharing function, you enjoy a power output of up to 8000 Watts per rack.

The RCP-2000 boasts a wide range of useful functions, which makes it perfect for use in data centres:

  • Auxiliary power output: 5V @ 0.3A / 12V @ 0.8A
  • Remote adjustment of output voltage.
  • DC OK Signal
  • AC OK Signal
  • Over Temperature Warning
  • Fan Fail Signal

As with the RCP-1600, remote adjustment of the output current is achieved by applying an external voltage to the relevant control terminals on the power supply.

Power Supply Unit

Voltage Adjus Range (Manual)

Voltage Adjust Range (Remote)

RCP-2000-12

10.5 ~ 14V

90 ~ 110% of nominal output voltage

RCP-2000-24

21 ~ 28V

RCP-2000-48

42 ~ 56V

A remote control unit is available for the RCP-2000 series power supplies under part number RKP-CMU1.

MEAN WELL RKP-CMU

This allows you to monitor the output voltage of the power supplies, the current draw and temperature level. Alarm signals can be set to warn of a power supply operating outside of expected parameters, giving an early indication that something could be wrong.

Since this article was originally published, MEAN WELL has added a further series to the range. This is the new 'digitalised' DRP-3200. 

MEAN WELL DRP-3200

This new power supply has a nominal power output of 3200 Watts and includes PMBus communications support. CANBus support is also available as an optional extra.

Of course one thing that is vitally important in data centres is reliability and MEAN WELL doesn’t disappoint here either.

MEAN WELL was established in 1982 by Mr Jerry Lim, who still heads up the company today. In 1986 MEAN WELL started to produce a range of standard switch mode power supplies. The core philosophy of the company is to design and manufacture power supplies, which are highly reliable and very affordable.

If you would like any further information, please do not hesitate to contact ADM on 1300 236 467.All of MEAN WELL’s rack mount power supplies are backed by a 5 year warranty.